CoolIT and Ecolab Ship 3MW Liquid Cooling Unit Aimed at AI Data Centers

CoolIT's CHx 3000 CDU, launched with Ecolab, delivers 3MW of cooling, serves up to 18 racks at 190kW each and ships from Q1 2027 for liquid-cooled AI data centers.

3 min read

CoolIT & Ecolab launch 3MW CDUVendors & Equipment
CoolIT & Ecolab launch 3MW CDUSpaceX-Imagery / pixabay

Why it matters

  • CoolIT CHx 3000 delivers 3MW of cooling at a 3°C approach temperature difference.
  • One unit cools up to 18 racks at 190kW per rack while consuming 75kW of power.
  • First units ship beginning Q1 2027.
  • Ecolab acquired CoolIT from KKR earlier this year; 3D TRASAR liquid-cooling monitoring launched in 2025.
  • Ecolab also announced a Siemens partnership covering power distribution, automation and digital twins.

The story

CoolIT and Ecolab have launched a cooling distribution unit rated at 3MW, the highest-capacity CDU CoolIT has built to date and a direct answer to the thermal demands of next-generation AI hardware such as Vera Rubin GPUs.

Ecolab announced the CoolIT CHx 3000 this week. The liquid-to-liquid CDU, deployed at row or facility level, delivers 3MW of cooling at a 3°C (37.4°F) approach temperature difference. Dual heat exchangers support 45°C (113°F) warm-water operation. Each unit draws 75kW of power.

The companies claim direct-to-chip cooling for high-density hardware at scale. One CHx 3000 can cool up to 18 racks at 190kW per rack. That figure comes from the vendors and reflects design targets rather than measured field deployments; no operator trials or customer contracts were disclosed. Units ship beginning Q1 2027.

What does this change for data center operators?

The practical question for operators is whether a single 3MW CDU simplifies liquid-cooled facility design. The answer, on paper, is consolidation: fewer units per hall, less pump overhead per rack, and warm-water operation that can cut chiller load. The 45°C warm-water rating allows heat rejection at temperatures suited to free cooling or heat reuse in many climates.

The unit also carries Ecolab's 3D TRASAR technology, which provides built-in, continuous coolant health monitoring. It tracks:

  • temperature
  • differential pressure
  • pH
  • conductivity
  • turbidity
  • flow rate
  • glycol concentration

Coolant chemistry matters more in direct-to-chip systems than in air cooling. Fouling or glycol drift in a loop serving 18 racks at 190kW each carries a 3.4MW thermal risk, which explains the emphasis on instrumentation.

A widening partner network

Ecolab paired the CDU launch with a series of engineering partnerships. This week it announced a deal with Siemens to combine Ecolab's liquid-cooling and CDU technology with Siemens' power distribution, automation, software and digital twin capabilities. The pairing targets the coupled problem of AI facilities: power and cooling must be designed together once racks pass 100kW.

Two further collaborations support the CHx 3000 itself. Ecolab said it is working with Alfa Laval, drawing on the Swedish company's heat exchanger and flow component expertise for the new CDU. Ecolab's virtual twin technology, developed with Dassault Systèmes, aims to link Technology Cooling System (TCS) and facility water system (FWS) models to simulate AI data center performance before construction.

From carpet cleaner to coolant

Ecolab's route into data center cooling is recent but rapid. Founded in 1923 to sell carpet cleaning products, the NYSE-listed company now supplies water treatment and monitoring across food, healthcare, hospitality and manufacturing industries. It launched a data center-centric version of its 3D TRASAR water monitoring product for liquid cooling in 2025, followed later that year by its own liquid cooling portfolio. It acquired CoolIT from private equity firm KKR earlier this year.

The acquisition placed a specialist direct-to-chip vendor inside a water chemistry group, and the CHx 3000 is the first flagship product of that combination. Ecolab chairman, president and CEO Christophe Beck framed the strategy in launch remarks.

"AI is advancing at an extraordinary pace, and the infrastructure behind it needs to advance just as fast," Beck said. "That's exactly what we're enabling today. For too long, cooling hardware, fluid management and digital technology have operated separately. We're bringing them together to help our customers get more computing power, faster, while using less water and energy. And we're just getting started."

Beck's closing line signals more product integrations ahead, and the Siemens partnership suggests Ecolab intends to sell cooling as part of a fuller data center infrastructure stack. Operators will be able to test the claims from Q1 2027, when the first CHx 3000 units ship.